With reliable good quality system, great standing and perfect consumer support, the series of products and solutions produced by our organization are exported to quite a few countries and regions for Netafim Drip Price, Irrigation Solutions, Center Pivot, In case you are intrigued in any of our products or want to focus on a personalized get, please sense totally free to contact us. We're wanting ahead to forming successful enterprise relationships with new shoppers across the world during the in close proximity to long term.
100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU Detail:

1.General Information:

1.1Introduction

It is a great honor for you to choose?dyjs.?YDJ-100 water resource telemetry terminal developed by our company, which has the functions of flow collection, valve control, data transmission and so on. It is mainly used in agricultural irrigation, urban water supply and other fields.

1.2 Safety information

Attention! Before unpacking, setting, or operating the device, read this manual thoroughly, and use and install the device.

1.3 Executive standard

Water Resources Monitoring Data Transmission Protocol?(SZY206-2016)

Basic Technical Conditions of Water Resources Monitoring Equipment?(SL426-2008)

2.operation

2.1 Functional specifications

Flow collection function: can be connected to 485 digital flowmeter, can output instantaneous flow and cumulative flow.

Regular reporting function: You can set the reporting interval by yourself.

Remote transmission function: data is transmitted to the data center through 4G network.

2.2 Indicator description

cczc
① Solar charging indicator light: the green light is steady on, indicating that the solar panel is working normally;
② Battery full indicator light: the red light brightness indicates how much the battery is charged;
③ Valve state indicator light: green light indicates that the valve is in open state, red light indicates that the valve is in closed state;
Communication indicator: Steady on indicates that the module is not online and is looking for a network. Blinking slowly: The network is registered. A fast blinking frequency indicates that a data connection is established.

2.3 Technical parameters

Radio frequency card

13.56MHz/ M1?card

Keyboard

Touch Key

Display

Chinese,192*96?Lattice

Power Supply

DC12V

?Power Consumption

Guard <3mA, data transmission <100mA

Instrument communication

RS485,9600,8N1

WI-FI

4G

Temperature

-20℃~50℃

Operating humidity

Less than?95%?(No condensation)

Material

?Shell?PC

level of protection

IP65

3.Maintain

3.1?Storage and maintenance

Storage: The equipment should be stored in a dry and ventilated place, away from direct sunlight.
Maintenance: The equipment should be maintained after a certain period of time (three months), including but not limited to the following:
① Whether there is water in the installation position of the equipment;
② Whether the battery of the equipment is sufficient;
③ Whether the wiring of the equipment is loose.

4.Install

4.1?open-box inspection

When the equipment is unpacked for the first time, please check whether the packing list is consistent with the physical object, and check whether there are missing parts or transportation damage. If you have any problem, please contact us in time.

List:

Serial Number

Name

Number

Unit

1

Water resource telemetry terminal

1

set

2

antenna

1

piece

3

Certification

1

sheet

4

?Instruction

1

set

5

Connect wire

4

piece

4.2?Installation Dimensions

4.3erminal instructions

ccdsc

Serial Number

Terminal Name

Function instructions

1

Solenoid Valves or Electric Butterfly Valve

Connect Solenoid Valves or Electric Butterfly Valve

2

Debug serial port

Connect computer serial port configuration parameters

3

Water meter input interface

Water meter signal acquisition and power supply

4

Horn and alarm switch interface

Audio output and switch alarm

5

Power interface

Connect solar cell and accumulator

6

Antenna interface

Connect 4G antenna

4.4Environmental requirements
Keep away from strong magnetic field or strong interference equipment (such as frequency conversion equipment, high voltage equipment, transformer, etc.); Do not install in corrosive environment.
5.Common faults and resolution
Serial Number Fault
Phenomenon
fault cause solution comment
1 No Connection SIM card is not installed, SIM card is not enabled with traffic services, SIM card arrears, Poor signal in the area. The server software is incorrectly configured. Check the fault causes one by one
2 Ultrasound can not read the data RS485 communication line is not properly connected or improperly connected; Ultrasonic flow meters have no flow value Reconnect the communication line and confirm whether the ultrasonic wave has flow value
3 The battery power supply is abnormal The terminals are not connected properly. Low battery. Reconnect the power supply terminal and measure the battery voltage (12V).
6.Quality assurance and technical services
6.1 quality guarantee
Product quality guarantee period of one year, in the warranty period of non-human fault, the company is responsible for free maintenance or replacement, such as equipment problems caused by other reasons, according to the extent of damage to charge a certain amount of maintenance fees.
6.2 Technical consulting
If you can’t solve the problem, please call our company, we will serve you wholeheartedly.


Product detail pictures:

100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU detail pictures

100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU detail pictures

100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU detail pictures

100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for 100% Original Rain Bed Irrigation System - “Yuhui” series Water resource telemetry terminal – DAYU, The product will supply to all over the world, such as: Uganda, Pakistan, Chile, Customer's satisfaction is always our quest, creating value for customers is always our duty, a long term mutual-beneficial business relationship is what we are doing for. We are an absolutely reliable partner for yourself in China. Of course, other services, like consulting, can be offered too.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By trameka milhouse from Florida - 2018.03.03 13:09
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Diego from New Zealand - 2018.11.11 19:52

    Leave Your Message

    Write your message here and send it to us
    主站蜘蛛池模板: 亚洲一级视频在线观看 | 日韩精品免费一区二区三区 | 免费看国产一级片 | 久久久久夜夜夜精品国产 | 色视频在线观看视频 | 在线观看黄免费 | 天堂在线中文字幕 | 欧美激情视频一区二区三区 | 国产精品一区在线免费观看 | 国产成人综合精品 | 国产日韩欧美在线视频免费观看 | 欧美成人第一页 | 免费a在线观看播放 | 最新精品亚洲成a人在线观看 | 免费观看呢日本天堂视频 | 九九九九在线精品免费视频 | 色狠狠色综合久久8狠狠色 色狠狠成人综合网 | 成年人黄色小视频 | 成年人网站免费在线观看 | 99久久亚洲| 日韩专区亚洲精品欧美专区 | 国产专区中文字幕 | 亚洲一区二区影视 | 最新中文字幕在线观看 | 天天擦天天干 | 国产女同志videos | 久久男女 | 黄色一级片免费看 | 在线视频国产一区 | 极品色天使在线婷婷天堂亚洲 | 欧美成人看片黄a免费 | 深夜福利91 | 日日综合网 | 国产久爱青草视频在线观看 | 黄视频网站在线观看 | 在线精品国产成人综合第一页 | 国产亚洲情侣一区二区无 | 一级特级欧美午夜片免费观看 | 污污网站免费入口链接 | 成年人三级网站 | 国产精品不卡视频 |