天天在线影院-天天在线综合网-天天澡天天干-天天澡天天摸天天爽免费-午夜伦理在线观看-午夜伦伦

“YUDI”series Ultrasonic water meter

Short Description:

“Yudi” series ultrasonic water meter is a flow measurement instrument based on the principle of ultrasonic time difference, mainly used in agricultural irrigation, urban water supply and other fields, can be used together with “Yuhui” series water resources telemetry terminal.


Product Detail

Product Tags

1.General Information:

1.1?Introduction

“Yudi” series ultrasonic water meter is a flow measurement instrument based on the principle of ultrasonic time difference, mainly used in agricultural irrigation, urban water supply and other fields, can be used together with “Yuhui” series water resources telemetry terminal.

Attentions:

  • transport should be handled with care and is not knocked against; Avoid storage in strong electromagnetic fields.
  • installation position should avoid flooding, freezing and pollution, and adequate maintenance space should be left.
  • table body is connected to pipe with excessive force to avoid damaging the sealant pad and causing water leakage.
  • is used to avoid strong impact and violent vibration.
  • should avoid use in a strongly acidic and alkaline environment and in an environment where salt fog is excessive, which accelerates the ageing of the product material and causes the product to fail to meet the hygiene standards.

Battery

  • when the battery is removed, please discard the product or contact us for repair.
  • End-of-life products have to have their batteries removed before they can be recycled,?Do not place the removed battery at will.Avoid contact with other metal objects or batteries to avoid fire or explosion.
  • Removes the waste battery to be treated in the environment or delivered to our company for unified recycling.
  • Do not short circuit the battery. Do not bring the battery near flame or water.
  • Do not overheat or weld the battery.
  • Do not expose the battery to violent physical impact.

2.Guide to the?Ultrasonic water meter

2.1 Wiring instructions

?????With aviation head:

①?The power supply is positive;②RS485_B;③RS485_A;④The power supply is negative

No aviation head:

Red:DC12V;Black:Power supply;Yellow:RS485_A; Blue:RS485_B

2.2?Water meter display

Accumulated flow:?X.XX m3 ??????

Instantaneous flow:??X.XXX m3/h

2.3?Data communications

Meter address (default):1

Communication protocol:MODBUS

Communication parameters:?9600BPS,8,N,1

2.4?Register address list:

data content Register address

Length

Data Length

Type of data

Unit

Instantaneous flow

0000H-0001H

2

4

float

m3/h

Accumulated?flow?(integer?part)

0002H-0003H

2

4

long

m3

Accumulated?flow?(decimal part)

0004H-0005H

2

4

float

m3

The integer?part of forward accumulated?flow

0006H-0007H

2

4

long

m3

The decimal part of forward accumulated?flow

0008H-0009H

2

4

float

m3

The integer?part of reverse accumulated?flow

000AH-000BH

2

4

long

m3

The decimal part of reverse accumulated?flow

000CH-000DH

2

4

float

m3

3.Technical parameters

performance

Parameter

turn down

R=80,100,120

pressure

<1.6 MPa

temperature grade

T30

Pressure loss

ΔP10

operating temperature

0℃~60℃

Display

Cumulative flow, instantaneous flow, battery status, failure, etc

Flow Unit

m3/h

operating mode

touch key-press

Communication

RS485, MODBUS,9600,8N1

Power supply

6V/2.4Ah?lithium battery

DC9-24V

Power Consumption

<0.1mW

waterproofing grade

IP68

way to install

Flange?clamp

Material

Tube material: modified reinforced nylon; Other:PC/ABS

4 Installation Guide

4.1 Select installation?site

When installation,?the minimum distance of the straight pipe section of the water meter is required to be ≥5D upstream and ≥3D downstream.?Distance from pump outlet ≥20D (D is the nominal diameter of pipe section),?and make sure the water is full of pipe.

Recommend installation?site

Installation site?are not recommended

圖片1 圖片2 圖片3 圖片4
The lowest point in the pipeline system is guaranteed to be full.A section of pipe that flows?vertically upward.Upstream straight pipe segment ≥5D. The lowest point in a piping system may be below the pipe.A section of pipe that flows vertically downward.Upstream straight pipe ≤3D.

4.2 Installation method

(1)Water meter connectioncsdcscdsc (2)Installation Angle

dsada

4.3 boundary dimension

sdcsd

nominal diameter

Water meter size(mm)

Flange?SIZE(mm)

H1

H2

L

M1

M2

ΦD1

ΦD2

DN50

54

158

84

112

96

125

103

DN65

64

173

84

112

96

145

124

DN80

68

174

84

112

96

160

134

5.open-box inspection

When the equipment is first unpacked and installed, please check whether the packing list is consistent with the physical object, check whether there are missing parts or transportation damage, if there is any problem, please contact our company in time.

List:

Serial number

Name

Quantity

Unit

1

Ultrasonic water meter

1

set

3

certification?

1

sheet

4

instruction book

1

set

5

Packing List

1

piece

6.Quality assurance and technical services

6.1 quality guarantee

Product quality guarantee period of one year, in the warranty period of non-human fault, the company is responsible for free maintenance or replacement, such as equipment problems caused by other reasons, according to the extent of damage to charge a certain amount of maintenance fees.

6.2 Technical consulting

If you can’t solve the problem, please call our company, we will serve you wholeheartedly.


  • Previous:
  • Next:

  • Leave Your Message

    Write your message here and send it to us
    主站蜘蛛池模板: 精品亚洲欧美高清不卡高清 | 日韩高清在线二区 | 国产簧片 | 久久精品一区 | 五月天精品视频播放在线观看 | 亚洲国产天堂在线mv网站 | 福利午夜 | 亚洲区 欧美区 | 国产香蕉久久精品综合网 | 自拍偷拍 欧美日韩 | 成人激情免费视频 | 久久精品无码一区二区日韩av | 亚洲天天综合网 | 一级做a爱过程免费视频韩国 | 黄色a网| 99精品热女视频专线 | 夜天干天干啦天干天天爽 | jizzjizz日本护士水多 | 国产综合视频在线观看一区 | 久久久久久久性高清毛片 | 成人免费视频国产 | 狠狠色狠狠色综合曰曰 | 日本免费一区二区三区在线看 | 伊人热人久久中文字幕 | 成人一区视频 | 欧美日韩在线播一区二区三区 | 国产视频成人 | 日本爽视频 | 老司机午夜精品视频 | 国产黄色在线网站 | 亚洲第一欧美 | 亚洲一区二区三区不卡视频 | 日韩国产欧美成人一区二区影院 | 天天操夜夜摸 | 亚洲永久中文字幕在线 | a高清免费毛片久久 | 国产人人干 | 日本精品视频一区二区三区 | xxxx久久| 国产一级毛片夜一级毛片 | 高清免费毛片 |